Natural gas to propane grill: the orifice and regulator test
Check the data plate and the manufacturer's instructions before buying parts. A safe conversion needs the correct propane orifices, valves, regulator, hose and burner setup for your grill.

Propane Facts
- Natural gas pressure
- about 4 in. w.c. at the manifold, depending on the appliance
- Propane pressure
- about 11 in. w.c. at the regulator outlet, if specified by the grill maker
- Heat per cubic foot
- roughly 1,000 for natural gas and 2,500 for propane vapor
- Propane orifice size
- often smaller, but use the manufacturer's part number rather than a ratio
- 40,000 BTU/h appliance
- about 0.44 gallon of propane per hour at full input
- 20 lb cylinder, full burn
- roughly 10 hours for a 40,000 BTU/h appliance, under stated assumptions
- Leak test mix
- Use the leak-detection method specified by the grill maker or gas supplier
Contents8 sections
- How do you confirm your grill can be converted, and find the kit?
- How do natural gas and propane orifices differ?
- How do you check the regulator outlet pressure and hose connection?
- How do you convert a natural gas to propane grill, step by step?
- What does the flame tell you about a wrong orifice or regulator?
- When should you not convert a grill?
- Key points
- People also ask
How do you confirm your grill can be converted, and find the kit?
Start with the data plate, the metal tag or sticker on the cart, frame or inside the cabinet door. It lists the model number, gas type and burner input in BTU/h. Photograph the plate before ordering parts.
Approval comes from the manufacturer, not from a hardware store. A grill is safety-tested as built, with a set gas, orifices and regulator. Search the owner's manual or the maker's support page for an LP conversion procedure for your exact model.
If the data plate says natural gas only and the maker lists no conversion procedure or kit, stop there. A manufacturer-approved conversion differs from a field modification. A field modification can void the appliance listing, warranty or insurance coverage, even if the grill appears to work. A universal kit is not automatically suitable for your grill.
Search the maker's parts site with the model number from the data plate. Match the kit part number against the manual or ask the maker to confirm it. Check the kit's listed burners, valves, hose, regulator and fittings before paying. It helps to understand how to check propane tank level before going further.
How do natural gas and propane orifices differ?
An orifice is the small metering nozzle at the end of a gas valve. Its opening controls how much gas reaches the burner tube. Propane vapor contains more energy per cubic foot than typical natural gas. The same heat output usually needs a smaller propane opening.
A 10,000 BTU/h burner uses roughly 10 cubic feet of typical natural gas each hour. The equivalent propane use is roughly 4 cubic feet per hour. Propane also reaches the manifold at higher pressure, often about 11 in. w.c. instead of about 4 in. w.c.
Those figures explain why the opening changes size. They cannot determine the correct orifice. BTU input alone is not enough, because burner design, gas pressure, and the appliance model also matter. Use the manufacturer's chart or parts diagram for the exact size. Before you commit to anything, it is worth looking at can propane tanks freeze.
Orifices may have a number stamped on the hex face or side. If yours is unmarked, use the manufacturer's parts diagram or have it identified by a qualified technician. The marking might show a drill number, diameter, or maker-specific code.
Conversion-kit availability is model-specific. You cannot confirm a compatible kit without the grill's make and model. Find those details on the rating label, then match them with the manufacturer's parts list. Do not choose a kit from BTU input alone.
Never enlarge an opening or substitute a drill bit. A wrong orifice can create an unsafe flame, poor heating, or excess carbon monoxide. The kit's part number and the manufacturer's chart control. We cover check for a propane leak with soapy water in its own article.
| Measure | Natural gas | Propane |
|---|---|---|
| Heat per cubic foot | about 1,000 BTU | about 2,500 BTU vapor |
| Manifold pressure | about 4 in. w.c. | about 11 in. w.c. |
| Orifice hole | larger in many designs | smaller in many designs |
| Gas source | house line | cylinder through a regulator |
How do you check the regulator outlet pressure and hose connection?
A regulator takes cylinder pressure, which changes with temperature, and holds it near the grill's working pressure. Many propane grills specify about 11 in. w.c. at the regulator outlet. Natural gas grills often use about 4 in. w.c. at the manifold.
Read the regulator label and the conversion instructions. The label should identify propane or LP, outlet pressure and capacity. Compare the replacement regulator's BTU/h capacity with the grill's total input, not just one burner. Match the manufacturer's required hose length, connector type and pressure rating.
A regulator with no readable label cannot be verified. Replace it with the exact manufacturer-specified part, or have a qualified technician select a listed replacement. An integrated regulator or conversion-specific valve may make a simple regulator swap unsuitable.
A measured pressure check uses a manometer at the grill's test port, if provided. Many grills lack one, so a technician must make the check. The hose end matters too. A propane hose often uses a Type 1, or QCC1, connector, but your manual controls.
How do you convert a natural gas to propane grill, step by step?
Work outdoors with the grill cold and the manual open to its conversion page. Use only the tools and parts listed there. Fixed orifices, conversion-specific valves and integrated regulators can prevent conversion by simple part changes.
A built-in grill fed by a house gas line needs special care. Local code may require a licensed gas fitter, gas utility or other authorized person to disconnect, cap, test or alter the line. The required person varies by jurisdiction, so check your local authority before starting.
Don't assume you can finish the appliance work yourself after a fitter handles the house line. The fitter may need to inspect the complete converted appliance, test the connection and approve the setup under local rules. Follow the fitter's instructions.
- Shut off the natural gas at the supply valve and disconnect the hose from the grill only if local rules and the manual permit it. Turn every burner knob to off.
- Lift out the grates, heat plates and burners as the manual shows, until you can see the valve ends and their orifices.
- Mark each air shutter's current position with a pencil line. Seat the socket fully on each natural-gas orifice and unscrew it slowly. Brass is soft, so stop if a part binds or the hex starts to round.
- Install the manufacturer-specified propane orifices by hand first. Snug them with the listed tool and torque only if the manual gives a torque value. Check every stamp against the parts list, since a side burner may use a different size.
- Set air shutters to the propane position in the manual. Refit the burners so each burner tube sits directly over its orifice. A tube beside the orifice can send fire toward the valve.
- Fit the specified propane regulator and hose as the manual shows. Follow its instructions for thread sealant, fitting orientation and torque. Sealant on the wrong connection can block the gas path or contaminate a valve. Never add sealant to a flare or compression surface unless the maker specifically allows it.
- Open the cylinder valve and carry out the manufacturer's leak-check procedure before lighting. Use an approved leak-detection solution on accessible joints if the instructions call for it. Growing bubbles mean close the cylinder, correct the fault and test again.
- Light a burner with the lid open, following the manual's lighting steps. Check the flame before cooking. Stop if the flame is unstable, yellow, lifting off the ports or producing soot.
What does the flame tell you about a wrong orifice or regulator?
Propane flames are usually blue, steady and quiet, with at most a faint yellow tip. They should sit on the burner ports without lifting off. Check each burner alone on high, with the lid open, after it has run for a few minutes.
A tripped flow limiter, a nearly empty cylinder or a blocked burner can all reduce output. The symptoms overlap rather than match exactly, so check the cylinder's fuel level, the regulator reset instructions and supply conditions before blaming one part.
Air shutters adjust in small steps. Let the burner cool, loosen the screw, move the collar slightly, tighten it and relight. If no setting gives a stable flame, stop using the grill and have the orifice, pressure and burner checked.
| What you see | Likely cause | What to do |
|---|---|---|
| Lazy yellow flame, soot on the grates | Incorrect gas metering, restricted air or dirty burner | Shut off and check the manual, burner and parts |
| Tall, noisy flame lifting off the ports | Too much air or pressure outside specification | Stop use and check the regulator and air setting |
| Small flame that shrinks on high | Supply or regulator fault | Follow the regulator reset procedure and check the cylinder |
| Fire or orange glow inside the burner tube | Tube not seated over the orifice, or a blockage | Turn off, let it cool, reseat and clean the tube |
| One burner differs from the rest | Wrong part in that burner, blocked ports or poor seating | Compare parts and have the burner checked |
When should you not convert a grill?
Skip the conversion when any of these is true:
- Kit gap: only a universal kit exists, not one listed for your model.
- Fixed parts: the orifices do not unscrew, or the grill uses integrated regulators or conversion-specific valves.
- Damage: a rust-thinned manifold, cracked burner tubes or a swollen hose.
- Built-in plumbing: local rules require qualified gas work, and no authorized fitter is available.
Key points
- Read the data plate before buying anything. Match every part number and orifice marking with the manufacturer's parts list before tightening anything.
- A yellow, sooty flame on propane usually means incorrect gas metering, restricted air or a burner problem.
- Follow local rules for gas-line work, fittings and who may perform the conversion.
People also ask
How long does a 20 lb cylinder last on a converted grill?
Use the grill's total input and your actual fill level. Runtime in hours is available propane BTU divided by total appliance input. The result changes with burner settings, weather and cylinder temperature.
Can I convert the grill back to natural gas later?
Often yes, if the maker lists a reverse conversion for that exact model. Keep the original parts labeled and follow the manufacturer's procedure. Reconnecting to a house gas line may require an authorized fitter under local code.
Can I drill an orifice to the right size myself?
No. The hole's size, finish and edge shape affect gas flow. Use the maker's replacement part or have a qualified technician identify the correct one.
How often should I check for leaks?
Follow the grill maker's schedule and check after any connection work, cylinder change or move. If you smell gas, leave the area and call your supplier or 911 from outside.
What if my regulator has no pressure printed on it?
Don't rely on an unmarked regulator. Check the manual for the required pressure, capacity, hose and connector, then install the specified listed part or have a qualified technician select it.